Steam or gas turbines are the heart of the industrial power generation facilities. TEP has the experience to handle these temperature critical applications, often operating at 1,000º F or higher. Multi-piece, double layer, and staggered joint design must be used on these large surface areas to prevent heat transfer at the joints. Utilizing the 3E NAIMA heat loss program, we can design insulation blankets to meet specific surface temperature or BTU/ square foot heat loss.